Wika lh-10 manual


















Electronics Accessories Engineered Solutions. Primary Flow Elements. Flow Switches. Air Flow Sensors. Display Gas Density Indicators. Transmit Gas Density Sensors.

WIKA Part of your business Solutions for pressure, temperature, force and level measurement, flow measurement, calibration and SF 6 gas solutions from WIKA are an integral component of our customers' business processes.

Model LH Submersible pressure sensor For level measurement. Model DI30 Digital indicator for panel mounting. Model DI Digital indicator with multi-function input For panel mounting, 48 x 24 mm. Model DI25 Digital indicator for panel mounting With multi-function input. Model DI35 High-quality digital indicator for panel mounting with multi-function input or with two inputs for standard signals. Model DI10 Digital indicator for panel mounting. Similar products. Model LS Submersible pressure sensor For general applications.

Model LH Submersible pressure sensor High-performance. Take a look at our information platform. Trade article Fundamentals of hydrostatic level measurement PDF. Job opportunities FAQ Unit calculator. Wish list - Documents 0 There are currently no documents on your wish list. The maximum number of 20 entries was reached. To receive your download link via e-mail, enter your address here: The e-mail address is invalid. Model Article. Wish list - Products 0 Note: There are currently no articles in your request list.

The maximum number of entries was reached. To receive your personal offer, we require some additional information from you. The output signal must be proportional to the prevailing pressure. If this is not the case, this may indicate a damaged diaphragm.

In the event of any faults, first check whether the submersible pressure transmitter is mounted correctly, mechanically and electrically. If faults cannot be eliminated by means of the measures listed above, shut down the submersible pressure transmitter immediately, and ensure that pressure is no longer present, and secure the instrument from being put back into operation inadvertently.

In this case, contact the manufacturer. If a return is needed, please follow the instructions given in chapter 9. Take sufficient precautionary measures. Strictly observe the following when shipping the submersible pressure transmitter:. All submersible pressure transmitters delivered to WIKA must be free from any kind of hazardous substances.

When returning the instrument, use the original packaging or a suitable transport package. Place shock-absorbent material evenly on all sides of the transport packaging. If possible, place a bag containing a desiccant inside the packaging. Label the shipment as carriage of a highly sensitive measuring instrument.

Mount the protection cap. Dispose of instrument components and packaging materials in an environmentally compatible way and in accordance with the country-specific waste disposal regulations. Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions.

Enter a new password. Vor Beginn aller Arbeiten Betriebsanleitung lesen! Contents Contents GB 1. General information 4 2. Safety 5 3. Specifications 8 4. Design and function 9 5. Transport, packaging and storage 10 6. Commissioning, operation 11 7. Maintenance and cleaning 13 8. Faults 13 9. Dismounting, return and disposal 14 Appendix 1: EC Declaration of conformity model LH 16 Declarations of conformity can be found online at www. General information 1.

All components are subject to stringent quality and environmental criteria during GB production. Safety The technical specifications contained in these operating instructions must be observed. Risk of injury should qualification be insufficient! Improper handling can result in considerable injury and damage to equipment. Skilled personnel Skilled personnel are understood to be personnel who, based on their technical training, knowledge of measurement and control technology and on their experience and knowledge of country-specific regulations, current standards and directives, are capable of carrying out the work described and independently recognising potential hazards.

Safety 2. Specifications 3. The given measuring ranges are also available in mbar, kPa and MPa. Output signals Signal type Signal Current 2-wire Design and function 4. Transport, packaging and storage 5. If the original packaging is not available, pack and store the instrument as described below: 1. Commissioning, operation 6.

Remove the protective cap if the medium is viscous or contaminated. Protection cap Internal diaphragm. Maintenance and cleaning 7. GB Repairs must only be carried out by the manufacturer. For information on returning the instrument see chapter 9. Diaphragm damaged, e.

Risk of burns! Let the instrument cool down sufficiently before dismounting it! During dismounting there is a risk of residual, dangerously hot media. Dismounting, return and disposal 9. Strictly observe the following when shipping the submersible pressure transmitter: GB All submersible pressure transmitters delivered to WIKA must be free from any kind of hazardous substances acids, bases, solutions, etc. To avoid damage: 1. Allgemeines 18 2.

Sicherheit 19 3. Technische Daten 22 4. Aufbau und Funktion 23 5.